TRV SELECTION GUIDE FOR STANDARD CAPACITY

Select Your Actuator.

MODELO # entajpu CAPILLARY LENGTH TEMPERATURA GAMA SENSO
 

 

 

HR90

 

 

 

Digital 7 day Programmable with integral temperature sensor. Works with V2040 and Danfoss RA2000 valves.

 

 

 

N / A

 

 

 

40-90F

 

 

 

integralo

 

 

 

 

 

 

 

 

T100B1035

 

 

A control with combined remote setpoint and sensor mounted on wall. Connected by a capillary tube to an actuator, which is mounted on the valve body.

 

 

 

6 ½ ft

 

 

 

48-79F

 

 

 

Izolita

 

 

 

T100B1043

 

 

A control with combined remote setpoint and sensor mounted on wall. Connected by a capillary tube to an actuator, which is mounted on the valve body.

 

 

 

16 ft

 

 

 

48-79F

 

 

 

Izolita

 

 

 

 

 

T100C1026

 

 

A control with remote setpoint and sensor mounted with setpoint dial and outside of heating cabinet; sensor mounted beneath heating coils in cold air return.

Dual Capillary.

 

 

 

Qty 2: 4 ½ ft each

 

 

 

48-79F

 

 

 

Izolita

 

 

 

 

 

 

T3019W0NA

 

 

Thermostatic head for M30X1.5 valves

 

 

N / A

 

 

34-82F

 

 

integralo

 

 

T3019DAW0NA

 

 

Thermostatic head for Danfoss RA valves

 

 

N / A

 

 

34-82F

 

 

integralo

 

 

T3019MMAW0

 

 

Thermostatic head for MMA/Macon valves

 

 

N / A

 

 

34-82F

 

 

integralo

 

 

 

T301920W0

 

 

 

Thermostatic head M30X1.5, remote sensor

 

 

 

6½ ft

 

 

 

34-82F

 

 

 

Izolita

Select your valve for 2 pipe steam or hot water.

MODELO # entajpu PIPO SIZE BODY PATTERN CV BTU / HR LIGOTIPO
 

 

 

V2040ASL15

 

 

 

Replaces most manual valve with minimum piping changes.

 

½ in

 

Horizontala Angulo

 

2.5

 

59,100

 

Fadenigitaj

 

V2040ASL20

 

¾ en

 

Horizontala Angulo

 

2.7

 

63,800

 

Fadenigitaj

 

V2040ASL25

 

1 en

 

Horizontala Angulo

 

2.7

 

70,500

 

Fadenigitaj

 

V2040DSL15

 

 

Especially suited for baseboards and straight runs where manual valves were not originally installed.

 

½ in

 

rektaj

 

2.5

 

59,100

 

Fadenigitaj

 

V2040DSL20

 

¾ en

 

rektaj

 

2.7

 

63,800

 

Fadenigitaj

 

V2040DSL25

 

1 en

 

rektaj

 

2.7

 

70,500

 

Fadenigitaj

 

V2040ESL15

 

 

 

Used where installation space is limited.

 

½ in

 

angulo

 

2.5

 

59,100

 

Fadenigitaj

 

V2040ESL20

 

¾ en

 

angulo

 

2.7

 

63,800

 

Fadenigitaj

 

V2040ESL25

 

1 en

 

angulo

 

2.7

 

70,500

 

Fadenigitaj

OR Select your valve for a 1 pipe steam system.

MODELO # entajpu PIPA GRANDO BODY PATTERN AIR VENT INCLUDED? LIGOTIPO
 

 

 

 

 

 

V2042HSL10

 

 

Angle pattern valve body for one pipe steam systems.

 

 

⅛ in

 

 

 

angulo

 

 

 

Ne

 

 

 

Fadenigitaj

 

 

 

V2043HSL10

Angle pattern valve body for one pipe steam systems.

Also includes steam air vent.

⅛ in angulo Jes Fadenigitaj

TRV SELECTION GUIDE FOR HIGH CAPACITY

Select Your Actuator.

MODELO # entajpu CAPILLARY LENGTH TEMPERATURA GAMA SENSO Komentoj
 

 

 

 

 

 

T104A1040

 

Self-contained controller with sensor, setpoint dial and valve actuator in one unit.

Adjustable limits. Mount horizontal. Not for use inside enclosures or in locations with restricted airflow around sensor. For V110 valves.

 

 

 

 

N / A

 

 

 

 

43-79F

 

 

 

 

integralo

 

 

 

 

Adjustable Limits

 

 

 

 

 

 

 

 

 

 

 

T104B1038

 

 

 

 

 

 

Self-contained controller with sensor, setpoint dial and valve actuator in one unit.

Adjustable limits. Mount horizontal. Not for use inside enclosures or in locations with restricted airflow around sensor. For V110 valves.

 

 

 

 

6 ½ ft

 

 

 

 

48-79F

 

 

 

 

Izolita

 

 

 

 

T104B1046

 

 

 

 

16 ft

 

 

 

 

48-79F

 

 

 

 

Izolita

 

 

 

 

 

 

 

T104C1036

 

Controller with remote setpoint and sensor normally mounted with setpoint dial mounted on outside cabinet or enclosure; sensor mounted beneath heating coils in cold air return. Double capillaries. For V110 valves.

 

 

 

 

Qty 2: 4 ½ ft each

 

 

 

 

48-79F

 

 

 

 

Izolita

 

 

 

 

 

 

T104F1512

 

 

Thermostatic radiator valve controller for use with V110 series valves. With remote temperature sensing and integral set point. Adjustable limits.

 

 

 

 

6 ½ ft

 

 

 

 

43-79F

 

 

 

 

Izolita

 

 

 

 

Adjustable Limits

Select your valve for 2 pipe steam or hot water.

MODELO # entajpu PIPO SIZE BODY PATTERN CV BTU / HR LIGOTIPO
 

 

 

 

 

V110D1000/U

 

 

 

 

 

 

 

 

 

 

 

 

 

Precise and automatic control of room temperature in two-pipe steam or hot water systems by modulating the flow of hot water

or steam through high capacity heating units.

 

½ in

 

rektaj

 

4.6

 

127,000

 

Fadenigitaj

 

V110D1008/U

 

¾ en

 

rektaj

 

5.8

 

162,000

 

Fadenigitaj

 

V110D1016/U

 

1 en

 

rektaj

 

7.0

 

193,000

 

Fadenigitaj

 

V110D1024/U

 

1 ¼ en

 

rektaj

 

8.0

 

193,000

 

Fadenigitaj

 

 

 

 

V110E1004/U

 

½ in

 

angulo

 

4.6

 

127,000

 

Fadenigitaj

 

V110E1012/U

 

¾ en

 

angulo

 

5.8

 

162,000

 

Fadenigitaj

 

V110E1020/U

 

1 en

 

angulo

 

7.0

 

193,000

 

Fadenigitaj

 

V110E1028/U

 

1 ¼ en

 

angulo

 

8.0

 

193,000

 

Fadenigitaj

 

 

 

V110F1002/U

 

½ in

 

Horizontala Angulo

 

4.6

 

127,000

 

Fadenigitaj

 

V110F1010/U

 

¾ en

 

Horizontala Angulo

 

5.8

 

162,000

 

Fadenigitaj

 

V110F1018/U

 

1 en

 

Horizontala Angulo

 

7.0

 

193,000

 

Fadenigitaj

Resideo Technologies, Inc.
1985 Douglas Drive Norda
Ora Valo, MN 55422
1-800-468-1502
rezidejo.comlogo

Dokumentoj/Rimedoj

resideo THERMOSTATIC RADIATOR VALVE [pdf] Uzantgvidilo
TERMOSTATIKA RADIANTA VALVO

Referencoj

lasu komenton

Via retpoŝta adreso ne estos publikigita. Bezonata kampoj estas markitaj *